Red Hat LINUX VIRTUAL SERVER 4.7 - ADMINISTRATION Installationsanleitung Seite 12

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 41
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 11
Array controller port failure
With DM-Multipath configured, a failure at any of these points will cause DM-Multipath to switch to the
alternate I/O path.
Figure 1.2, Active/Passive Multipath Configuration with T wo RAID Devices shows a more complex
active/passive configuration with 2 HBAs on the server, 2 SAN switches, and 2 RAID devices with 2 RAID
controllers each.
Figure 1.2. Act ive/Passive Multipath Configurat ion with Two RAID Devices
As in the example shown in Figure 1.1, Active/Passive Multipath Configuration with One RAID Device,
there are two I/O paths to each RAID device. With DM-Multipath configured, a failure at any of the points
of the I/O path to either of the RAID devices will cause DM-Multipath to switch to the alternate I/O path for
that device.
Figure 1.3, Active/Active Multipath Configuration with One RAID Device” shows an active/active
configuration with 2 HBAs on the server, 1 SAN switch, and 2 RAID controllers. There are four I/O paths
from the server to a storage device:
hba1 to controller1
hba1 to controller2
hba2 to controller1
hba2 to controller2
In this configuration, I/O can be spread among those four paths.
Chapter 1. Device Mapper Multipathing